| Class or division |
|
Notes |
1.1 1.2 |
1.3 |
1.4 |
1.5 |
1.6 |
2.1 |
2.2 |
2.3 gas zone A |
2.3 gas Zone B |
3 |
4.1 |
4.2 |
4.3 |
5.1 |
5.2 |
6.1 liquids PG I zone A |
7 |
8 liquids only |
| Explosives |
1.1 and 1.2 |
A |
* |
* |
* |
* |
* |
X |
X |
X |
X |
X |
X |
X |
X |
X |
X |
X |
X |
X |
| Explosives |
1.3 |
|
* |
* |
* |
* |
* |
X |
|
X |
X |
X |
|
X |
X |
X |
X |
X |
|
X |
| Explosives |
1.4 |
|
* |
* |
* |
* |
* |
O |
|
O |
O |
O |
|
O |
|
|
|
O |
|
O |
| Very insensitive explosives |
1.5 |
A |
* |
* |
* |
* |
* |
X |
X |
X |
X |
X |
X |
X |
X |
X |
X |
X |
X |
X |
| Extremely insensitive explosives |
1.6 |
|
* |
* |
* |
* |
* |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Flammable gases |
2.1 |
|
X |
X |
O |
X |
|
|
|
X |
O |
|
|
|
|
|
|
O |
O |
|
| Non-toxic, non-flammable gases |
2.2 |
|
X |
|
|
X |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Poisonous gas Zone A |
2.3 |
|
X |
X |
O |
X |
|
X |
|
|
|
X |
X |
X |
X |
X |
X |
|
|
X |
| Poisonous gas Zone B |
2.3 |
|
X |
X |
O |
X |
|
O |
|
|
|
O |
O |
O |
O |
O |
O |
|
|
O |
| Flammable liquids |
3 |
|
X |
X |
O |
X |
|
|
|
X |
O |
|
|
|
|
O |
|
X |
|
|
| Flammable solids |
4.1 |
|
X |
|
|
X |
|
|
|
X |
O |
|
|
|
|
|
|
X |
|
O |
| Spontaneously combustible materials |
4.2 |
|
X |
X |
O |
X |
|
|
|
X |
O |
|
|
|
|
|
|
X |
|
X |
| Dangerous when wet materials |
4.3 |
|
X |
X |
|
X |
|
|
|
X |
O |
|
|
|
|
|
|
X |
|
O |
| Oxidizers |
5.1 |
A |
X |
X |
|
X |
|
|
|
X |
O |
O |
|
|
|
|
|
X |
|
O |
| Organic peroxides |
5.2 |
|
X |
X |
|
X |
|
|
|
X |
O |
|
|
|
|
|
|
X |
|
O |
| Poisonous liquids PG I Zone A |
6.1 |
|
X |
X |
O |
X |
|
O |
|
|
|
X |
X |
X |
X |
X |
X |
|
|
X |
| Radioactive materials |
7 |
|
X |
|
|
X |
|
O |
|
|
|
|
|
|
|
|
|
|
|
|
| Corrosive liquids |
8 |
|
X |
X |
O |
X |
|
|
|
X |
O |
|
O |
X |
O |
O |
O |
X |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Check SDS section 11: Toxicology |
|
* check explosive compatibility tab |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Hazard Zone A: LC50 ≤ 200ppm |
|
Blank cell indicates no restrictions |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Hazard Zone B: LC50>200ppm and ≤1,000ppm |
|
X don’t load together |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Hazard Zone C: LC50 > 1,000ppm and ≤ 3,000ppm |
|
O spill containers required |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Hazard Zone D: LC50 >3,000ppm and ≤5,000ppm |
|
A ammonium nitrate chem. And fertilizer can be loaded despite X |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| LC 50: Lethal Concentration by inhalation that kills 50% of the test subjects exposed. |
|
When there are two hazards the most restrictive rule applies. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|