When there are two hazards the most restrictive rule applies.

Class or division   Notes 1.1 1.2 1.3 1.4 1.5 1.6 2.1 2.2 2.3 gas zone A 2.3 gas Zone B 3 4.1 4.2 4.3 5.1 5.2 6.1 liquids PG I zone A 7 8 liquids only
Explosives 1.1 and 1.2 A * * * * * X X X X X X X X X X X X X
Explosives 1.3   * * * * * X   X X X   X X X X X   X
Explosives 1.4   * * * * * O   O O O   O       O   O
Very insensitive explosives 1.5 A * * * * * X X X X X X X X X X X X X
Extremely insensitive explosives 1.6   * * * * *                          
Flammable gases 2.1   X X O X       X O             O O  
Non-toxic, non-flammable gases 2.2   X     X                            
Poisonous gas Zone A 2.3   X X O X   X       X X X X X X     X
Poisonous gas Zone B 2.3   X X O X   O       O O O O O O     O
Flammable liquids 3   X X O X       X O         O   X    
Flammable solids 4.1   X     X       X O             X   O
Spontaneously combustible materials 4.2   X X O X       X O             X   X
Dangerous when wet materials 4.3   X X   X       X O             X   O
Oxidizers 5.1 A X X   X       X O O           X   O
Organic peroxides 5.2   X X   X       X O             X   O
Poisonous liquids PG I Zone A 6.1   X X O X   O       X X X X X X     X
Radioactive materials 7   X     X   O                        
Corrosive liquids 8   X X O X       X O   O X O O O X    
                                         
Check SDS section 11: Toxicology   * check explosive compatibility tab                              
Hazard Zone A: LC50 200ppm   Blank cell indicates no restrictions                                    
Hazard Zone B: LC50>200ppm and 1,000ppm   X don’t load together                                    
Hazard Zone C: LC50 > 1,000ppm and ≤ 3,000ppm   O spill containers required                                
Hazard Zone D: LC50 >3,000ppm and ≤5,000ppm   A ammonium nitrate chem. And fertilizer can be loaded despite X                                    
LC 50: Lethal Concentration by inhalation that kills 50% of the test subjects exposed.   When there are two hazards the most restrictive rule applies.                                    