Class or division | | Notes | 1.1 1.2 | 1.3 | 1.4 | 1.5 | 1.6 | 2.1 | 2.2 | 2.3 gas zone A | 2.3 gas Zone B | 3 | 4.1 | 4.2 | 4.3 | 5.1 | 5.2 | 6.1 liquids PG I zone A | 7 | 8 liquids only |
Explosives | 1.1 and 1.2 | A | * | * | * | * | * | X | X | X | X | X | X | X | X | X | X | X | X | X |
Explosives | 1.3 | | * | * | * | * | * | X | | X | X | X | | X | X | X | X | X | | X |
Explosives | 1.4 | | * | * | * | * | * | O | | O | O | O | | O | | | | O | | O |
Very insensitive explosives | 1.5 | A | * | * | * | * | * | X | X | X | X | X | X | X | X | X | X | X | X | X |
Extremely insensitive explosives | 1.6 | | * | * | * | * | * | | | | | | | | | | | | | |
Flammable gases | 2.1 | | X | X | O | X | | | | X | O | | | | | | | O | O | |
Non-toxic, non-flammable gases | 2.2 | | X | | | X | | | | | | | | | | | | | | |
Poisonous gas Zone A | 2.3 | | X | X | O | X | | X | | | | X | X | X | X | X | X | | | X |
Poisonous gas Zone B | 2.3 | | X | X | O | X | | O | | | | O | O | O | O | O | O | | | O |
Flammable liquids | 3 | | X | X | O | X | | | | X | O | | | | | O | | X | | |
Flammable solids | 4.1 | | X | | | X | | | | X | O | | | | | | | X | | O |
Spontaneously combustible materials | 4.2 | | X | X | O | X | | | | X | O | | | | | | | X | | X |
Dangerous when wet materials | 4.3 | | X | X | | X | | | | X | O | | | | | | | X | | O |
Oxidizers | 5.1 | A | X | X | | X | | | | X | O | O | | | | | | X | | O |
Organic peroxides | 5.2 | | X | X | | X | | | | X | O | | | | | | | X | | O |
Poisonous liquids PG I Zone A | 6.1 | | X | X | O | X | | O | | | | X | X | X | X | X | X | | | X |
Radioactive materials | 7 | | X | | | X | | O | | | | | | | | | | | | |
Corrosive liquids | 8 | | X | X | O | X | | | | X | O | | O | X | O | O | O | X | | |
| | | | | | | | | | | | | | | | | | | | |
Check SDS section 11: Toxicology | | * check explosive compatibility tab | | | | | | | | | | | | | | | |
Hazard Zone A: LC50 ≤ 200ppm | | Blank cell indicates no restrictions | | | | | | | | | | | | | | | | | | |
Hazard Zone B: LC50>200ppm and ≤1,000ppm | | X don’t load together | | | | | | | | | | | | | | | | | | |
Hazard Zone C: LC50 > 1,000ppm and ≤ 3,000ppm | | O spill containers required | | | | | | | | | | | | | | | | |
Hazard Zone D: LC50 >3,000ppm and ≤5,000ppm | | A ammonium nitrate chem. And fertilizer can be loaded despite X | | | | | | | | | | | | | | | | | | |
LC 50: Lethal Concentration by inhalation that kills 50% of the test subjects exposed. | | When there are two hazards the most restrictive rule applies. | | | | | | | | | | | | | | | | | | |